E1139: Ggate/TNVIP/Telnet, -PCO printer was not freed on brutal disconnections

Product: DSA listener
Platform: All
Status: Fixed in 6.4, fix available for 6.3
Last updated: 2006-10-04 14:57:10

If a TNVIP or TELNET session associated with a printer (-PCO) was
disconnected 'brutally' by the client (e.g. if the client
disconnected the connection to Ggate manually because there was no
response to the session connect request, typically because the
mainframe was down), then the cleanup routines failed and the printer
was left in a listening state. Any subsequent attempt to allocate
that printer would fail.

This problem has only been seen in situations where the mainframe has
been booted while automated clients are running, and the automated
clients have a short time-out on connection attempts, then disconnect
brutally, and try again.

Work-around, wait for the connect to time-out. Note that the connect
time-out (default 30 seconds) can be adjusted using the -cw parameter.