E1154: Glink, one sided binary sessions failed

Product: Glink Windows
Platform: All
Status: Fixed for 6.2.9, 7.2.6, 8.0.7 and 8.1
Last updated: 2007-01-24 12:42:41

If the host requested Glink to send binary, but did not send binary
itself, then Glink accepted to send binary, but didn't do it. In the
only observed case a POSIX subsystem running under Windows and
reached by a Telnet session requested that Glink send in binary while
not sending binary itself. Glink continued to send Telnet NewLine
(CR-LF) instead of only CR (as it should have done in binary). This
caused various problems since both the CR and the LF were then
delivered to POSIX. A double prompt in reply to CR in the command
line was an obvious symptom.

Work around is to configure tty to ignore CR on input. This can be
done in the profile, or dynamically using stty igncr.